Back to references

Gas production choke

Choke type
DCV-C200

Choke size & rating
3″ API Class 10.000

Actuation
Pneumatic modulating

Existing problem

A: Short meantime between failure due to erosion
B: Cv value limitation, 2 choke sizes are need to cover flow requirements

Causes of problem

A: Contaminants and high delta P in fluid creating high erosion at valve seats
B: Initial high delta p requires small Cv value. Well pressure drops relatively fast and then a full bore valve is required to eliminate production losses

Solutions

A: Dux seats are given the design and material choice less sensible for erosion
B: In the Duxvalves a low noise trim can easily be replaced by a full bore trim to minimize delta P

Results

All valves work to clients satisfactory

Website door Webton