Back to references

Level control valve

Choke type
DCV-C/E100

Choke size & rating
1″ ASME Class 1.500

Actuation
Pneumatic Modulating

Existing problem

A: Short meantime between failure due to erosion
B: Leakage over stem
C: Low seat tightness

Causes of problem

A: Contaminants in fluid
B: Low quality stem sealing
C: Leakage over seat due to “wrong” design & material choice

Solutions

A: Dux seats are given the design and material choice less sensible for erosion
B: Triple seal bonnet design
C: Seat tightness equal to Class VI of IEC 60534-4

Results

Most of the existing valves are replaced by Dux due to client contentment

Website door Webton