Level control valve
Choke type
DCV-C600
Choke size & rating
6″ ASME Class 1.500
Actuation
Hydraulic modulating
Existing problem
Short meantime between failure
Causes of problem
A: Contaminants in fluid creating high erosion at valve seats
B: Valves are mounted upside down. Sand is gathered on top of the cage which causes that valve stick and will not open icw actuator overload
Solutions
A: Dux seats are given the design and material choice less sensible for erosion
B: The upside down mounting does not influence the stroke of the rotating Duxvalve
Results
After extensive period of testing the seats look new and no sticking effect was seen
Increase of flow capacity and less downtime

No sign of erosion at seat