Existing problem

A: Short meantime between failure due to erosion
B: Seat tightness

Causes of problem

A: Contaminants in fluid
B: Suitability of existing valve

Solutions

A: Dux seats are given the design and material choice less sensible for erosion
B: Dux guarantees for a much longer period a high seat tightness
(standard to class V of the IEC 60534-4)

Results

Field inspection learned after a 12 times longer mtbf  that disc show no erosion tracks at all